Comparison of Mechanical Vapour Compression Evaporator Technologies
Author
McLafferty, Victor
Metadata
Show full item recordAbstract
The energy efficiency, heat exchanger area requirements, and solids handling performance of Mechanical Vapour Compression (MVC) evaporation were compared to a proposed evaporator configuration called Mechanical Vapour Compression Flash Distillation (MVC-FD). Steady-state models were developed for both systems, and their thermal performance was compared. It was found that the MVC-FD configuration significantly increases specific energy consumption and heat exchanger requirements when compared to the standard MVC configuration. A steady-state bulk fouling model was developed for CaSO4-H2O-NaCl to determine whether fouling is reduced using the MVC-FD configuration. It was found that fouling is increased in this system due to the solubility properties of CaSO4. Fouling was also examined for the NaCl-H2O fluid system. It was found that the fouling can be substantially reduced by the MVC-FD system because fouling in this system is driven primarily by liquid volume change.